Model Number
Features:
- Designed for commercial, industrial and residential
applications
- Loads up to 40 Amps per pole
- Providing direct 24 hour control of most loads
- 1 to 10 ON/OFF operations each day with minimum
ON/OFF times of 1 hour
- Manual override
- All models equipped with one CUTOUT (ON), one OFF
tripper and three
day-skipper screws
- Day-skipper screws in skipper dial to omit operation
on selected days of the week
Models with Carryover (Suffix C)
- Minimum of 16 hours carryover operation for
maintaining preset schedules during
power failures
- Carryover automatically rewinds when power resumes;
only one hour of rewinding
time required for every two hours of power outage.
- 4PST models are ideal for 3-phase load control
Specifications:
Switch Rating: Same as T100 Series. 4PST models also rated 7.5 HP (28 FLA)
208 VAC;
10 HP (28 FLA) 240 VAC 3-phase.
Note: 4 pole models will not fit in standard or plastic
enclosure; only in NEMA 3R steel
enclosure. T170CR series only available in NEMA 3R steel enclosure.
Model Number: T171CR
Switch: SPST Clock Motor Volts AC 60 Hz: 125
Shipping Weight lb./Kg: 5.0/2.27